Kemp Support, how can we help?

The latest application delivery knowledge and expertise at your fingertips.

Offline Licensing Grayed Out

 

Information

 

Summary:

A permanent virtual unit cannot perform offline licensing

Environment:

Product: LoadMaster

Version: Any

Platform: Virtual

Application: Any

Question/Problem Description:

The Offline Licensing option is grayed out for a permanent virtual unit.

Steps to Reproduce:  
Error Message:  
Defect Number: PD-14028
Enhancement Number:  
Cause: The /one4net/local_cfg/_INITIAL_SPLA file is preventing the LoadMaster from being able to perform offline licensing.
Resolution:

Xroot into device and remove the /one4net/local_cfg/_INITIAL_SPLA file using the following commands:

>cd ..

>rm /one4net/local_cfg/_INITIAL_SPLA file

Workaround:  
Notes:  