LoadMaster not sending health checks to down real server
Information
Summary: |
Real server is marked down and LoadMaster is not sending health check packets. Logs show timeout waiting for data. |
Environment: |
Product: LoadMaster Version: Any Platform: Hardware Application: Any |
Question/Problem Description: |
Real server is marked down and tcpdump from the LoadMaster is empty. No health check packets are being sent to the server and logs show timeout waiting for data. |
Steps to Reproduce: | |
Error Message: | Real Server failing - Timeout waiting for connection |
Defect Number: | |
Enhancement Number: | |
Cause: | The interface link is down due to a bad network cable. |
Resolution: | Eth2 interface that health checks are being sent out of is showing no link. Changing the network cable resolved the issue. |
Workaround: | |
Notes: |
Was this article helpful?
0 out of 0 found this helpful