Kemp Support, how can we help?

The latest application delivery knowledge and expertise at your fingertips.

Empty result of Data Retention query

 

Information

 

Summary:

The result of data retention public for NAT query is empty.

Environment:

Product: Flowmon Data Retention

Version: Any

Platform: Flowmon Collector

Question/Problem Description:

The output of data retention query is empty.

Steps to Reproduce:  
Error Message:  
Defect Number:  
Enhancement Number:  
Cause: The segment for public IP is incorrect set.
Resolution: Is necessary to check the segment for requested public IP if all flow sources for Public Sources and Private sources if are selected correct.
Workaround: In Flowmon Monitoring center is possible to check which  flow source is monitoring your public IP address.
Notes:  

Was this article helpful?