Information

 

Summary:

It is not possible to obtain additional information about the flow source via SNMP.

Environment:

Product: Flowmon Collector

Version: Any

Platform: Any

Question/Problem Description:

 

Steps to Reproduce:  
Error Message: Cannot connect to the device.
Defect Number:  
Enhancement Number:  
Cause: SNMP timeout is too short. The default value is 250 ms. 
Resolution:

It is possible to change the timeout in Configuration Center - FMC Configuration - Sources - SNMP info update timeout (ms). 

SNMP response can be measured via CLI with the command:

time snmpbulkwalk -Cr20 -v 2c -c "<community_string>" -r 1 -t 10 <flow_source_IP> ifDescr

The response time might vary with every request, so one measurement doesn't have to provide reliable results.

Workaround:  