Kemp Support, how can we help?

The latest application delivery knowledge and expertise at your fingertips.

Flowmon ADS integration with Veeam Backup & Replication

 

Information

 

Summary:

The article describes details about ADS integration with Veeam Backup & Replication.

Environment:

Product: Flowmon ADS

Version: Any

Platform: Any

Question/Problem Description:

ADS events are not propagated to Veeam.

Steps to Reproduce:  
Error Message:  
Defect Number:  
Enhancement Number:  
Cause:  
Resolution:

The log file with debugging details is located in:

/data/components/apps/log/veeam-api.log

The most common issue is missing reverse DNS records for machines protected by Veeam. The Veeam API requires the machine's IP and hostname to create an event properly. 

This issue can be indicated by the API error message:

Unable to detect machine by presented parameters.

This message will be visible in the log file.

To find correct hostnames in Veeam, the device inventory can be checked:
https://helpcenter.veeam.com/docs/backup/vsphere/working_area.html?ver=120

These names should be the same as hostnames returned by the DNS server.

Workaround:  
Notes:

https://support.kemptechnologies.com/hc/en-us/articles/24784530926477-Flowmon-ADS-integration-with-Veeam-Backup-Replication


Was this article helpful?
0 out of 0 found this helpful

Comments