Profile history is short and it is not possible to change the quota
Information
Summary: |
Profile history is shorter than needed, and it is not possible to change the profile quota. |
Environment: |
Product: Flowmon Collector Version: Any Platform: Any |
Question/Problem Description: |
Why is it not possible to change the quota? |
Steps to Reproduce: | |
Error Message: | |
Defect Number: | |
Enhancement Number: | |
Cause: | The profile is of shadow type. Shadow profiles don't save their own copy of flow data. They use flow data of their parent profile. |
Resolution: |
Change the quota of the parent profile. Standalone collector Monitoring Center - Profiles - Edit profile or Configuration Center - Resource Manager Distributed architecture Monitoring Center - Profiles - Edit profile or Configuration Center - Distributed architecture - choose Source group - icon on the right "Open FCC" - Resource Manager |
Workaround: | |
Notes: |
Was this article helpful?