Profile history is short and it is not possible to change the quota

 

Information

 

Summary:

Profile history is shorter than needed, and it is not possible to change the profile quota. 

Environment:

Product: Flowmon Collector

Version: Any

Platform: Any

Question/Problem Description:

Why is it not possible to change the quota?

Steps to Reproduce:  
Error Message:  
Defect Number:  
Enhancement Number:  
Cause: The profile is of shadow type. Shadow profiles don't save their own copy of flow data. They use flow data of their parent profile. 
Resolution:

Change the quota of the parent profile.

Standalone collector

Monitoring Center - Profiles - Edit profile

or

Configuration Center - Resource Manager

Distributed architecture

Monitoring Center - Profiles - Edit profile

or

Configuration Center - Distributed architecture - choose Source group - icon on the right "Open FCC" - Resource Manager

Workaround:  
Notes:  