How can we help?

The latest application delivery knowledge and expertise at your fingertips.

Kemp 360 Central Firmware Upgrade Path

This article provides a firmware upgrade path for all versions of Kemp 360 Central.

 

Upgrading from any version pre v1.9 or pre 1.25.2

If upgrading from v1.6 or an earlier version, you will only be able to upgrade to v1.9. If you'd like to deploy on the latest version of firmware, a redeployment is required.

If upgrading from any version between v1.9 and v1.23 to the latest version, please reach out to Kemp Support as an increased disk size was enforced in v1.25.2. Kemp Support must increase the disk size within the VM. Alternatively, a redeployment of Central using the latest version obtained from here would come with the increased disk size pre-configured.

 

Upgrading from any version between v1.25.2 and v1.27

Upgrade to 2.0 and reboot your 360 Central device.

Upgrade to 2.10 and reboot your 360 Central device.

Upgrade to 2.12 (Latest GA) and reboot your Kemp 360 Central device.

 

Upgrading from any version between v2.0 and v2.9

Upgrade to 2.10 and reboot your Kemp 360 Central device.

Upgrade to 2.12 (Latest GA) and reboot your Kemp 360 Central device.

 

Upgrading from v2.10 or later

Upgrade to 2.12 (Latest GA) and reboot your Kemp 360 Central device.

 

Release notes are available for all firmware versions of Kemp 360 Central.