HA failover causes the Shared IP to become inaccessible.
Information
Summary: |
HA failover causes the LoadMaster Shared IP to become inaccessible. |
Environment: |
Product: LoadMaster Version: Any Platform: Any Application: Any |
Question/Problem Description: |
Why aren't we able to access the Shared IP after an HA failover? |
Steps to Reproduce: | |
Error Message: | |
Defect Number: | |
Enhancement Number: | |
Cause: | The Shared IP's MAC address hasn't been purged from the switches in the network path yet. |
Resolution: | Either fail back over to the other unit in the HA pair, or manually purge the ARP entry from the switch in your environment. |
Workaround: | |
Notes: |
Was this article helpful?
0 out of 0 found this helpful