Kemp Support, how can we help?

The latest application delivery knowledge and expertise at your fingertips.

VA devices with 10Gb/s monitoring interfaces

 

Information

 

Summary:

10Gb/s speed monitoring interfaces on virtual appliance

Environment:

Product: Flowmon

Version: ALL

Platform: VA - vmWare

Question/Problem Description:

Monitoring interfaces on VA device are 1Gb/s although the physical ports are 10GB/s and license is for 10Gb/s devices as well.

Steps to Reproduce:  
Error Message:  
Defect Number:  
Enhancement Number:  
Cause: Bad settings of adapter type of network adapter in virtual appliance
Resolution: Change Adapter type of network adapter in VA device settings from E1000 to VMXNET3
Workaround:  
Notes:  