Information

 

Summary: 

Unable to add an additional NIC on a Virtual LoadMaster (VLM) that has a VLAN/Bonded interface configured.

Environment:

Product: LoadMaster

Version: Any

Platform: Virtual 

Application: Any 

Question/Problem Description: 

There are six network interfaces currently configured on the VLM.  When adding the seventh, the interface is not displayed. 

Steps to Reproduce:  
Error Message:  
Defect Number:  PD-18110
Enhancement Number:  
Cause: 
  • The problem lies at the very bottom of the network configuration stack.
  • The code that is at fault was implemented before virtual machines were supported.  I.e. when Kemp only sold hardware.
Resolution:  Remove the VLAN or bonded interface prior to adding the additional NIC
Workaround: All NICs should be added prior to configuring VLANs/Bonded interfaces
Notes: https://support.kemptechnologies.com/hc/en-us/articles/5169339575181-Bonding-VLAN-and-VXLAN